VONARIS-M vertical

Simple and flexible preassembly through the revolutionary central connection technology.

A real plus to planning freedom as well as a hint of modernity and style.
Heat-Output-Calculator
Brochure

Overview of models

The convectors and heating walls manufactured by VOGEL&NOOT meet numerous internationally recognised quality standards and the manufacturing processes at all of the production sites have been ISO certified.

quality marks

Varying dimensions and different designs regarding the number of layers and convection sheets lead to a wide range of models, suitable for different requiremets.

Type VSV-M

VSV-M overview of modelsVSV-M 10

VSV-M overview of modelsVSV-M 11

VSV-M overview of modelsVSV-M 20

VSV-M overview of modelsVSV-M 21

Model VSV-M 10 VSV-M 11 VSV-M 20 VSV-M 21
Height 1600 1800 2000 1600 1800 2000 1600 1800 2000 1600 1800 2000
Length 214 - 862 mm
Depth 68 68 93 93
Increments 72 mm

 

Connections Connections: 2 x external thread G 3/4“, bottom centre

5 bar Test overpressure (standard design): 5 bar

Max. positive operating pressure (high-pressure design):
8 bar

Maximal operating temperature Max. operating temperature: 110 °C

Technical information

Get an overview of the most important technical data. For further information, please download the featured pdf files.

Connection modes - double-pipe operation

It is easy to set the precise values required without using any special tools (see drawings).

VSV-M double-pipe operation

 

The radiator will be delivered with a fitted protective cap. After removing the protective cap (item A), the following thermostat heads can be installed directly onto the built-in valve (item B): „RA 2000“, or „RAW“ from Danfoss, „VK“ from Heimeier, „D“ from Herz, „thera DA“ from MNG, and „UNI XD“ from Oventrop.

Adjustment tips:
• Remove protective cap and sensor
• Lift the adjusting ring and turn it anti-clockwise, to the setting
   required – the set value (1, 2, ...7, N) needs to be directly in line with the marker.
• Presetting is possible in steps of 0.5 between 1 and 7. The „N“setting, cancels all presetting.

 

Connection modes - single-pipe operation

For VHV-M models no valve default setting is necessary, as the valve is delivered factory-adjusted (default setting "N").

VSV-M single-pipe operation

 

The radiator valve (VHV-M models) and the connection set (VSV-M models) will both be delivered with a fitted protective cap. After removing the protective cap (item A), the following thermostat heads can be installed directly onto the built-in valve (item B): „RA 2000“, or „RAW“ from Danfoss, „VK“ from Heimeier, „D“ from Herz, „thera DA“ from MNG, and „UNI XD“ from Oventrop.

Please note:
When fitting the single-pipe operation connection set, ensure that the circulation retarder is installed in the water return.

 

Downloads

Here you can download all relevant data in different file formats.

Colours

The VONARIS-M vertical design heating panel is available in 71 different colours.

RAL COLOURS

  • RAL9016 Traffic White
  • RAL 9010 Pure White
  • RAL 9001 Cream White
  • RAL 250-2 Lemon Glow
  • RAL 1023 Traffic Yellow
  • RAL 1012 Lemon Yellow
  • RAL 1004 Golden Yellow
  • RAL 1027 Curry
  • RAL 6034 Pastel Turquoise
  • RAL 5014 Pastel TurquoisePigeon Blue
  • RAL 5009 Azure Blue
  • RAL 5015 Sky Blue
  • RAL 5017 Traffic Blue
  • RAL 5022 Night Blue
  • RAL 5002 Ultramarine Blue
  • RAL 5001 Green Blue
  • RAL 9005 Jet Black
  • RAL 7021 Black Grey
  • RAL 1033 Dahlia Yellow
  • RAL 2003 Pastel Orange
  • RAL 2004 Pure Orange
  • RAL 3000 Flame Red
  • RAL 3005 Wine Red
  • RAL 4002 Red Violet
  • RAL 4007 Purple Violet
  • RAL 4008 Signal Violet
  • RAL 290 70 20 Mauve Haze
  • RAL 290 40 45 Mystic Purple
  • RAL 4009 Pastel Violet
  • RAL 3015 Light Pink
  • RAL 3014 Antique Pink
  • RAL 6019 Pastel Green
  • RAL 120 80 60 Modern green
  • RAL 120 70 70 E-Green
  • RAL 150 60 60 Green Apple
  • RAL 6033 Mint Turquoise
  • RAL 6004 Blue Green
  • RAL 8017 Chocolate Brown
  • RAL 8019 Grey Brown
  • RAL 040 80 05 White Coffee
  • RAL 7035 Light Grey
  • RAL 7040 Window Grey
  • RAL 7001 Silver Grey
  • RAL 7037 Dusty Grey
  • RAL 7030 Stone Grey
  • RAL 7013 Brown Grey
  • RAL 7015 Slate Grey
  • RAL 7016 Anthracite Grey
  • RAL 7024 Graphite Grey
  • RAL 9006 White Aluminium
  • RAL 9007 Grey Aluminium

The colours shown here are not binding. Colour variations are possible due to print-technical reasons. Further colours available on request!

SANITARY COLOURS

  • S0075 Jasmine
  • S0091 Pergamon
  • S0094 Natura
  • S0087 Bahama Beige
  • S0084 Anemone
  • S0077 Magnolia
  • S0164 Banana
  • S0088 Manhatten

The colours shown here are not binding. Colour variations are possible due to print-technical reasons. Further colours available on request!

SPECIAL COLOURS

  • S0145 Creme White
  • S0142 White Textured
  • S0141 Black Textured
  • S0147 Anodic Brown
  • S0148 Anodic Black
  • S0149 Anodic Natura
  • S0201 Metal Alu
  • S0102 Metal Grey
  • S0146 Anodic Bronze
  • S0104 Metal Black
  • S0144 Brown Grey
  • S0143 Light Grey

The colours shown here are not binding. Colour variations are possible due to print-technical reasons. Further colours available on request!

Accessories

Get an overview of our wide range of accessories for our convectors and heating panels.

CE Marking and Declaration of Performance (DoP)

The European Union Construction Products Regulation requires that building products, including the radiators and the convectors without an integrated heat source, must be CE-marked in accordance with relevant harmonized product standards EN 442 and the Declaration of Performance (DoP). The CE marking means that each product meets the manufacturing process requirements of the product according to the provisions of manufacture, testing and delivery. The regulation came into force on July 1st, 2013.

Rettig ICC products are CE-marked and the Declaration of Performance of Rettig ICC and its reference documents, Annexes D and Annexes M describing the detailed performance of the products, are available according to the Construction Products Regulation.  See the current DoP of RICC attached and the linked document files.


VDI-Dataset

VDI-DATASET 

Download our new VDI-Dataset "Radiators and Fanconvectors" from the BDH-Portal.

BDH-Portal

Heat-Output-Calculator

New Heat-Output-Calculator

Try our new Heat-Output-Calculator now!

Try it now

Modernisation

In Europe, more than 40% of the CO2 emissions are caused by buildings. To update the whole heating system is one of the most important measures, to protect our environment sustainable.

cf. Prof. Rainer Hirschberg , VDI Nachrichten, Aachen 2006